Skip to content
FastTool

Measure on an Image or PDF Plan

Set a known length on any photo or PDF floor plan, then measure distances, room areas, perimeters and angles with click uncertainty.

Runs in your browser. Nothing is uploaded.

Your plan and scale

Sample open: apartment-1br-floor-plan.png (1400 × 1060 px, 120 px = 1.00 m).

Sample takeoffs

1. Calibration method
Scale source

Accepts dots or commas (such as 8.40 or 3,60). Line span: 1008.0 px.

2. Display units and precision
± px

0.25 to 10 px per point. Propagates into ± length and ± area.

Plan canvas and takeoff

  • 120.0 px/mActive scale8.40 m = 1008.0 px (±0.21%)
  • 21.60 ± 0.12 m²Total areaPerimeter 18.60 ± 0.05 m
  • 3.200 ± 0.019 mTotal linear length1 distance or path item
  • 3 itemsMeasurements1 area · 1 distance · 1 angle
Fit
Click corners around a room to measure its area, then press Enter or Finish. Use arrow keys (Alt+Arrows for 1 px) and Enter for keyboard placement.
Measurement takeoff schedule (edit names inline)
ID Name Mode Result (± uncertainty) Details Action
M1 Area 21.60 ± 0.12 m² Perimeter 18.60 ± 0.05 m (4 corners)
M2 Distance 3.200 ± 0.019 m 384.0 px span
M3 Angle 90.0° ± 0.6° Right angle (reflex 270.0°)
Totals (shared calibration scale) 21.60 ± 0.12 m² Linear: 3.200 ± 0.019 m · Area perimeter: 18.60 ± 0.05 m

How to use

  1. Drop a PDF plan or photo above, or explore the 1-bedroom floor plan already open on the canvas.
  2. Calibrate from a long printed wall or scale bar in 2-point mode, or choose a PDF drawing ratio like 1:50.
  3. Use the 4× pixel loupe and optional 0° / 45° / 90° snap to place exact wall corners.
  4. Switch between Distance, Path, Area, and Angle to measure rooms, runs of piping or fencing, and roof pitch.
  5. Rename rows directly in the takeoff table, switch units at any time, and download CSV, PNG, or annotated PDF.

Worked example

Input

The built-in 1-bedroom apartment plan (1400 × 1060 px), drawn at 120 pixels per meter with an 8.40 m north wall.

Settings

2-point calibration on the 8.40 m north wall (1008 px), ±1.5 px click uncertainty, meters and square meters.

Result

Living room reads 21.60 ± 0.12 m² (perimeter 18.60 ± 0.05 m), counter reads 3.200 ± 0.019 m, corner reads 90.0°.

With ±1.5 px isotropic endpoint uncertainty, any two-point line has pixel-length uncertainty √2 × 1.5 = 2.12 px. Across the 1008 px north wall, relative scale error is 2.12 ÷ 1008 = 0.21%.

scale s = 8.40 m ÷ 1008 px = 0.008333 m/px (120.0 px/m, σ_s / s = 0.210%) living room: 540 × 576 px = 311,040 px² → 311,040 × s² = 21.60 m² ± 0.12 m²

Switch to the Short 0.80 m doorway trap preset to calibrate on the 96 px bedroom doorway instead. Scale error jumps to 2.12 ÷ 96 = 2.21%, widening the exact same living room result to 21.6 ± 1.0 m².

How it works

Polygon area and self-intersection checks

Closed room areas use the Shoelace formula over ordered corner coordinates (x_i, y_i). Non-adjacent edges are checked for crossings so accidental bow-tie corner order cannot quietly subtract floor area.

A_px = ½ |∑ (x_i y_{i+1} − x_{i+1} y_i)|, A = s² × A_px ∂A_px / ∂x_i = ±½ (y_{i+1} − y_{i−1}), ∂A_px / ∂y_i = ±½ (x_{i−1} − x_{i+1})

First-order click uncertainty propagation

Endpoint placement error σ_px propagates through calibration and shape corners by first-order uncorrelated quadrature (NIST Technical Note 1297). Uncertainties are rounded using the Particle Data Group two-digit rule.

σ_D = √[ (D × σ_s / s)² + s² σ_px² ∑ ‖∇_{P_i} L_px‖² ] σ_A = √[ (2 A × σ_s / s)² + ¼ s⁴ σ_px² ∑ ‖P_{i+1} − P_{i−1}‖² ]

PDF 72-point geometry and architectural ratios

PDF pages define physical sheet dimensions in points at 72 points per inch (Adobe PDF 32000-1:2008, §8.3.2). Paper ratio mode multiplies that sheet size by metric or architect's scale ratios such as 1:50 or 1/4 in = 1 ft (1:48). Sources checked 29 November 2026.

FAQ

Should I calibrate from a known wall length or enter a 1:100 paper scale?

Use 2-point known length whenever a dimension or scale bar is drawn on the plan. Fit-to-page exports shrink paper ratios by 3% to 7%, while a drawn wall shrinks along with the rooms.

Why does calibrating on a long wall reduce the ± uncertainty so much?

Clicking two ends has roughly ±2.1 pixels of span error regardless of line length. Spreading 2.1 pixels across a 600 px wall gives 0.35% scale error, whereas a 96 px doorway gives 2.21% error.

How do I measure an L-shaped room or a room with a bay window?

Choose Area and click every corner in order around the room perimeter, then press Enter or select Finish. The Shoelace formula handles any number of straight walls without splitting the room into rectangles.

How does the 3-point angle tool show roof pitch and ramp grade?

Click a point along the horizontal level line, then the corner vertex, then a point up the slope. Alongside degrees, the details column converts acute angles into percent grade and X:12 roof pitch.

Can I measure microscope photos, PCBs, or sewing patterns?

Yes. Switch units to micrometers (µm), millimeters (mm), or inches (in), then calibrate on your microscope bar, pin pitch, or pattern square.

Are my floor plans or PDFs uploaded to a server?

No. Every PDF page and image is rendered, measured, and exported inside your browser on your own device.

Step by step: how to measure distances and room areas on a PDF floor plan or photo.

Updated