Skip to content
FastTool

Does your result agree with the accepted value? Testing with uncertainty

Percentage difference tells you how far your result sits from a textbook value, while uncertainty tells you whether random scatter explains that gap.

Updated · Uses the free Uncertainty Propagation Calculator, which runs in your browser

Short answer

Compute the discrepancy d = |x − x_ref| and the combined standard uncertainty u_d = √(u² + u_ref²), or just u when u_ref is zero. Divide to get z = d / u_d. Under the standard k = 2 (~95%) rule, z ≤ 2 means your measurement agrees, while z > 2 signals systematic bias. With expanded uncertainties U = 2u, |E_n| = d / √(U² + U_ref²) ≤ 1 gives the identical result.

Open the Uncertainty Propagation Calculator

How to read z and E_n in three clear bands

Propagate your input uncertainties into x ± u in the same unit as x_ref, then compare d against u_d:

Standard interpretation of the normalized difference z and expanded-uncertainty ratio |E_n|
z = d / u_d (1σ) |E_n| = d / U_d (k = 2) What to write in your conclusion
z ≤ 1.0 |E_n| ≤ 0.5 Clear agreement: the accepted value lies inside one standard uncertainty of your measurement.
1.0 < z ≤ 2.0 0.5 < |E_n| ≤ 1.0 Compatible (~95% interval): consistent within two standard uncertainties; no systematic fault required.
z > 2.0 |E_n| > 1.0 Does not agree: the gap exceeds random scatter; inspect your setup for systematic bias.

Some school courses ask only whether x_ref falls inside x ± Δx from half-range readings or added percentages. Check your syllabus rule and state which criterion you used alongside the number.

Why percentage difference alone gets the verdict backwards

Students often assume any percentage error below 5% means an experiment worked. Without comparing against u, a 0.8% discrepancy can fail while a 4% discrepancy agrees cleanly. These two made-up resistance checks against an exact 100.0 Ω standard show why:

Two made-up comparisons against an exact 100.0 Ω standard showing why percentage error misleads
Illustrative case Result x ± u Percentage error z = d / u Verdict
Precision bridge (u = 0.1%) 99.20 ± 0.10 Ω 0.80% 8.0 Disagrees (8σ away; e.g. unzeroed lead resistance)
Bench meters (u = 5.0%) 96.0 ± 5.0 Ω 4.0% 0.80 Agrees (0.8σ away; gap sits inside random noise)

Percentage error measures accuracy relative to the true value, whereas u measures your precision. Agreement asks whether the inaccuracy is larger than your imprecision can explain.

Worked example: pendulum gravity compared with standard g_n

Open the Uncertainty Propagation Calculator and click Try an example. Type NIST’s exact standard gravity 9.80665 into Accepted value, or load this calculation directly:

  1. Inputs: formula g = 4*pi^2*L/T^2 with L = 0.9500 ± 0.0010 m and T = 1.955 ± 0.005 s.
  2. Propagated result: g = 9.813 ± 0.051 m/s² at k = 1, or 9.81 ± 0.10 m/s² at k = 2.
  3. Discrepancy: d = |9.81273 − 9.80665| = 0.0061 m/s² (+0.062% of the accepted value).
  4. Normalized score: z = 0.00608 / 0.05124 = 0.12 standard uncertainties (|E_n| = 0.06 at k = 2). Since 0.12 ≤ 2, the calculator reports that the result agrees with the accepted value.

Now introduce a systematic mistake by measuring to the top hook of a 30 mm bob instead of its center. Entering L = 0.9350 ± 0.0010 m at T = 1.955 ± 0.005 s gives g = 9.658 ± 0.050 m/s². The percentage error is only −1.5%, yet d = 0.149 m/s² yields z = 2.95, so the result disagrees. When your quantity comes from a graph gradient, find the slope uncertainty first in the Line of Best Fit with Error Bars.

When the reference value has its own uncertainty

Defined constants like g_n = 9.80665 m/s² have zero uncertainty, so leave Its uncertainty (optional) blank. When comparing measured 215.4 ± 1.8 Ω against a reference resistor rated 220.0 ± 2.2 Ω (1σ), enter 2.2 in Its uncertainty (optional):

  • Combined difference uncertainty: u_d = √(1.8² + 2.2²) = √8.08 = 2.84 Ω.
  • Normalized difference: z = |215.4 − 220.0| / 2.84 = 1.62. That agrees within 2u_d, whereas ignoring u_ref gives z = 2.56.

Common mistakes

  • Mixing units between x and x_ref. Comparing g in cm/s² or density in g/cm³ against SI values creates a 100× or 1000× error immediately.
  • Dividing by an expanded k = 2 uncertainty while still using a cutoff of 2. Dividing by U = 2u gives |E_n|, whose threshold is 1.0, not 2.0.
  • Inflating input error bars after seeing z > 2. Keep your real instrument uncertainties and explain the physical bias in your discussion instead.

When a single z-test is the wrong check

With only 2 or 3 repeat readings, effective degrees of freedom ν_eff are tiny. At ν_eff = 2, the 95% Student-t factor is 4.30 rather than 2.0. Check the Expanded uncertainty step in the Uncertainty Propagation Calculator, which computes Welch–Satterthwaite ν_eff and k_95 automatically.

Sources

Spotted a mistake in this guide? Email contact@fasttool.app. We reply within 7 business days.

Open the Uncertainty Propagation Calculator